Sign in freeLED flash patterns, likely causes, and fixes for every LiftMaster / Chamberlain platform.
LiftMaster commercial trolley, hoist and jackshaft operators (T, GT, APT, J, H, HJ, GH) with a Logic 4 or Logic 5 board. Both boards use the same E1 to E10 error codes.
Where to look: The MAS (maintenance alert) LED on the logic board. It flashes the error number, pauses, and repeats. The board also has status LEDs for power, stop, open, close, limits and the safety inputs. Those are not the code.
E1: Maintenance alert
The service interval set in the Maintenance Alert System (cycles or months) has been reached. The door still runs.
1. Service the door and operator. 2. Reset the maintenance alert the way the operator's manual shows.
E2: No RPM input while opening
The board saw no RPM (motor turning) signal on an open. A jammed door, slipping clutch or belt, loose RPM sensor or interrupter, or broken RPM wiring.
1. Check the door moves freely by hand with the operator disconnected. 2. Check the clutch and drive belt. 3. Check the RPM sensor, its interrupter and the wiring to the board.
E3: Max run timer expired
The door ran longer than the max run timer allows without reaching a limit. Limits out of adjustment, a slipping clutch, or a door that binds.
1. Check the door travels freely. 2. Check and reset the limits. 3. Check the clutch. 4. Re-learn the max run timer per the manual if the travel changed.
E4: Obstruction while closing
An obstruction was sensed while closing, or the RPM signal was lost while closing.
1. Clear the doorway. 2. Check the photo eyes and safety edge. 3. Check the door for binding near the floor. 4. Check the RPM sensor if nothing was in the way.
E5: Button held over 2 minutes
An open, close or stop input was held on for more than 2 minutes. A stuck station button or shorted control wiring.
1. Disconnect the control stations one at a time. 2. Replace a stuck station. 3. Check the control wiring for a short.
E6: Invalid option card
An option card is plugged in that the board can't use, or it has failed.
1. Check the card is a LiftMaster card for this board. 2. Reseat it. 3. Remove it to see if the code clears, then replace it.
E7: Safety device fault
A monitored entrapment device (LMEP photo eye or edge) has faulted or been unplugged for more than 2 minutes.
1. Check the LMEP devices and their lights. 2. Check the wiring at the LMEP terminals. 3. Replace a failed device.
E8: Brownout
The supply voltage dropped too low.
1. Measure the incoming voltage while the motor runs. 2. Check the wire size and length of the supply run. 3. Look for other loads on the same circuit.
E9: Motor moved when it shouldn't
The board saw the motor turn at a time it wasn't running it. A door drifting under its own weight, a brake not holding, or a stuck relay.
1. Check the door balance and springs. 2. Check the brake. 3. If both are fine, suspect the board's relays.
E10: Motor phase jumper changed
The motor phase jumper was moved outside programming mode.
1. Put the jumper back, or set it in programming mode per the manual. 2. Check the door runs the right way.
Most residential LiftMaster and Chamberlain openers without arrow lights. Count the flashes of the LED next to the Learn button. Openers and replacement logic boards made since early 2022 no longer flash codes 1, 2 and 4, so no flash there does not prove the sensors are fine.
Where to look: The small LED next to the Learn button on the motor unit (behind the light lens or on the side panel). It flashes a number, pauses, and repeats.
Safety sensor wire open
A wire to a safety reversing sensor is broken or disconnected.
1. Check the sensor wires for breaks or loose connections at the sensors and at the motor head. 2. Look for staple damage along the run. 3. Repair or reconnect.
Safety sensor wire shorted or reversed
The sensor wires are shorted together, or the white and white/black wires are swapped.
1. Look for a staple through the wire or bare wires touching. 2. Connect white to terminal 2 and white/black to terminal 3 (grey). 3. Replace the wire run if damaged.
Door control wire shorted
The wall control's LED or screen is not lit: its wiring is shorted, often by a staple.
1. Check the wall control wires for a short. 2. If the control's LED or screen is on but it doesn't work, replace the door control.
Safety sensors misaligned
The sending sensor's light is steady but the receiving sensor's light is dim or flashing.
1. Loosen the receiving sensor's wing nut. 2. Clean the lens. 3. Aim until its light is steady, then retighten. 4. Make sure the bracket and track are secure.
No RPM signal (mechanical stoppage)
The opener saw no motor travel in the first second. Usually the door, a spring, gears, the trolley or the RPM sensor.
1. If it now runs normally, unplug for 5 seconds to clear the code. 2. Hums then stops: check door balance, broken spring, locks, trolley against the stop bolt, chain or belt tension, then capacitor, gears and motor. Let a hot motor cool 45 minutes. 3. White shavings mean stripped gears. 4. Moves under 6 to 8 inches: check the RPM sensor harness and interrupter cup, replace the RPM sensor if needed.
Motor circuit failure
The logic board's motor circuit has failed. The motor itself rarely fails.
1. Replace the receiver logic board.
Newer myQ residential openers that flash an up arrow, then a down arrow. For the 8500W and other Wi-Fi jackshaft models, use their own chart.
Where to look: The up and down arrow lights on the motor unit's end panel, next to the Learn button. Count the up arrow flashes, then the down arrow flashes.
Safety sensors blocked, misaligned or disconnected
Door closes then reverses, or won't close. Main lights may flash 10 times.
1. Clear the beam. 2. Check both sensor lights and align. 3. Check the connections and wire run. 4. Replace the sensors if the code stays.
Safety sensor wires reversed or shorted
Door won't close, or moves an inch or two and comes back.
1. Match wire colours at both ends. 2. Look for a pinched or stapled wire. 3. Replace the damaged run.
No RPM detected
Opener hums or clicks, and the door moves less than 6 to 8 inches or not at all.
1. On a jackshaft with the release pulled, reconnect the door. 2. Check door balance and springs. 3. Check the travel module or RPM sensor and the gears.
Unexpected door movement
Door drifts down after opening, or was moved by hand (jackshaft).
1. Run a balance test. 2. If it was moved by hand, reconnect the emergency release.
Logic board component failure
Opener doesn't respond normally and no other code explains it.
1. Unplug for 5 seconds (and disconnect any battery backup). 2. If the code returns, replace the logic board.
Cable tension monitor (wall-mount jackshaft)
Door closes then returns to open, or won't move. The remote light may flash five times.
1. Do not run the door if a cable is loose. 2. Reconnect the monitor and check its roller and wire. 3. Fix the cable before returning to service.
8500W / RJO70, 98022 / RJO101, 98032 only.
Resistance while closing
Door reverses, stops or struggles while closing.
1. Clear obstructions. 2. Check and lube rollers and hinges. 3. Reset the close limit if the door runs past the floor.
Resistance while opening
Door stops before fully open.
1. Clear obstructions. 2. Balance-test the door; out of balance means spring work.
RPM lost while closing
Door stops and reverses just before the floor.
1. Clear the path. 2. Check rollers and hinges. 3. Inspect the travel module if it continues.
RPM lost while opening
Door stops before fully open.
1. Clear the path, check rollers and hinges. 2. Balance-test with the release pulled. 3. Look for a broken torsion spring.
Unrecognized travel module
Door reverses to open or won't move.
1. Check the model number. 2. Confirm the right travel module in the manual. 3. Replace it if it's the wrong one or failed.
Remote light required
App commands, schedules and timer-to-close don't run. Wall control and remotes still work.
1. Install and power a myQ-compatible remote light. 2. Re-pair it if needed, or turn off schedules in the app.
8500W / RJO70, 98022 / RJO101, 98032 only.
Wall-mount Wi-Fi jackshaft openers. They flash the up arrow, then the down arrow. A few codes mean something different from the general arrow chart, so use this one for these models.
Where to look: The up and down arrows on the opener flash the code. Count the up arrow flashes, then the down arrow flashes.
Safety sensors not connected
Door won't close. The safety reversing sensors are not installed or not connected, or a wire may be cut.
Inspect the sensor wires for a disconnected or cut wire.
Safety sensor wire shorted or reversed
Door won't close. A sensor wire is shorted or reversed.
1. Inspect the sensor wire at every staple and connection point. 2. Replace or correct the wire.
Door control wire shorted or control faulty
The door control does not work. Its wires are shorted, or the door control is faulty.
1. Inspect the wiring at every staple and connection point. 2. Replace or correct the wire.
Safety sensors misaligned or briefly blocked
Door won't close. The sensors are misaligned or were blocked for a moment.
1. Realign both sensors until both LEDs are steady. 2. Clear anything hanging on the door that blocks the sensor path.
Moves 6 to 8 inches, then stops or reverses
Binding or an obstruction, such as a broken spring or a door lock. Or a wiring or travel module fault.
1. Run the door by hand and check for binding. 2. Check the wiring at the travel module and logic board. 3. Replace the travel module if needed.
Code 1-5 has three symptoms on this page. Match the one you see.
Single click, no movement
Binding or an obstruction, or a logic board fault.
1. Run the door by hand and check for binding. 2. Replace the logic board if needed.
Code 1-5 has three symptoms on this page. Match the one you see.
Hums 1 to 2 seconds, no movement
Binding or an obstruction, or a motor fault.
1. Run the door by hand and check for binding. 2. Replace the motor if needed.
Code 1-5 has three symptoms on this page. Match the one you see.
Door coasts after stopping
Travel is not set to the coasting position, or the door is out of balance.
1. Program travel to the coasting position. 2. Or have a trained technician balance the door.
Logic board fault
No movement or sound.
Replace the logic board.
Moves slightly, then stops
The page gives no cause.
1. Run the opener again. 2. If it keeps happening, replace the logic board.
Battery backup charging circuit error
The battery status LED flashes green all the time.
Replace the logic board.
Cable tension monitor removed
Door won't close, or reverses during travel. Two cable tension monitors were installed and one was removed.
Unplug the operator and plug it back in three times to relearn the monitor.
Stops or reverses while moving
The door is binding or sticking, or travel needs reprogramming.
1. Run the door by hand and check for binding. 2. If it binds or sticks, call a trained door systems technician. 3. If not, reprogram travel.
Travel module communication error
The operator runs about 6 to 8 inches, stops and reverses.
1. Check the travel module connections. 2. Replace the module if needed.
Safety sensors misaligned or briefly blocked
Door won't close. The sensors are misaligned or were blocked for a moment.
1. Realign both sensors until both LEDs are steady. 2. Clear anything hanging on the door that blocks the sensor path.
myQ Remote LED Light needed
Door won't close from Timer-to-Close or the myQ app. The myQ Remote LED Light is not installed or not programmed.
Install the myQ Remote LED Light and program it to the opener.
Chamberlain: "Light-Duty models do NOT require the MyQ Remote LED to use this feature." On those models, replace the logic board instead.
Chamberlain-built DC belt and chain units. Count the flashes of the LED next to the Learn button.
Where to look: The diagnostic LED next to the Learn button. It flashes a number of times, then pauses before repeating.
Safety reversing sensor circuit fault
Door will not close and the lights flash. One or both sensor lights are not steady.
1. Check the sensor wires for a short, such as a staple in a wire. 2. Check for black and white wires reversed. 3. Check for broken or disconnected wires. Replace or reattach as needed.
Chamberlain: "Any garage door opener or replacement logic board manufactured after February 3, 2022, will no longer have this feature."
Safety reversing sensor circuit fault
Door will not close and the lights flash. One or both sensor lights are not steady.
1. Check the sensor wires for a short, such as a staple in a wire. 2. Check for black and white wires reversed. 3. Check for broken or disconnected wires. Replace or reattach as needed.
Chamberlain: "Any garage door opener or replacement logic board manufactured after February 3, 2022, will no longer have this feature."
Door control not working
The LED on the door control is not lit. The wiring may be shorted, for example between the red and white terminals.
1. Check the door control wiring for a short and replace as needed. 2. Disconnect the wires at the door control and touch them together. 3. If the opener runs, replace the door control.
Safety sensors misaligned
The sending sensor light is steady but the receiving sensor light is dim or flashing. The sensors are misaligned or the track is moving.
1. Loosen the wing nut on the receiving sensor. 2. Clean the lens and realign it until its light is steady. 3. Tighten the wing nut and secure the brackets. 4. Make sure the door track is firmly fixed to the wall.
Chamberlain: "Any garage door opener or replacement logic board manufactured after February 3, 2022, will no longer have this feature."
No RPM in the first second
No movement, a grinding sound, or 0 to 6 inches of door travel.
Check for a stop or obstruction, bad motor gears, a disconnected encoder harness, an open armature, or brush failure.
Chamberlain lists these causes but no separate fix.
RPM pulses after the motor turned off
The door coasts down or up after reaching its limits.
1. Disconnect the door from the opener and see if it coasts down or opens on its own. 2. If the door is not too heavy or out of spec for the opener, replace the motor.
Motor short
No movement or sound.
Chamberlain lists no fix for this code.
Force reversal, up direction
The door stops during the open cycle.
Run the opener again. It should step up to the next force setting on its own.
Max force, down direction
The door stops and reverses during the close cycle.
1. Reset the limits and forces. 2. If that does not fix it, look for a door problem.
Force reversal, down direction
The door stops and reverses during the close cycle.
Run the opener again. It should step up to the next force setting on its own.
Max force, up direction
The door stops during the open cycle.
1. Reset the limits and forces. 2. If that does not fix it, look for a door problem.
Bad CRC (data error check)
No movement and no sound. The board failed its cyclic redundancy check.
Replace the logic board.